Microneedle-Based Detection of Ketone Bodies along with Glucose and Lactate: Toward Real-Time Continuous Interstitial Fluid Monitoring of Diabetic Ketosis and Ketoacidosis
ANALYTICAL CHEMISTRY
Authors: Teymourian, Hazhir; Moonla, Chochanon; Tehrani, Farshad; Vargas, Eva; Aghavali, Reza; Barfidokht, Abbas; Tangkuaram, Tanin; Mercier, Patrick P.; Dassau, Eyal; Wang, Joseph
Abstract
Diabetic ketoacidosis (DKA), a severe complication of diabetes mellitus with potentially fatal consequences, is characterized by hyperglycemia and metabolic acidosis due to the accumulation of ketone bodies, which requires people with diabetes to monitor both glucose and ketone bodies. However, despite major advances in diabetes management mainly since the emergence of new-generation continuous glucose monitoring (CGM) devices capable of in vivo monitoring of glucose directly in the interstitial fluid (ISF), the continuous monitoring of ketone bodies is yet to be addressed. Here, we present the first use of a real-time continuous ketone bodies monitoring (CKM) microneedle platform. The system is based on the electrochemical monitoring of beta-hydroxybutyrate (HB) as the dominant biomarker of ketone formation. Such real-time HB detection has been realized using the beta-hydroxybutyrate dehydrogenase (HBD) enzymatic reaction and by addressing the major challenges associated with the stable confinement of the enzyme/cofactor couple (HBD/NAD(+)) and with a stable and selective low-potential fouling-free anodic detection of NADH. The resulting CKM microneedle device displays an attractive analytical performance, with high sensitivity (with low detection limit, 50 mu M), high selectivity in the presence of potential interferences, along with good stability during prolonged operation in artificial ISF. The potential applicability of this microneedle sensor toward minimally invasive monitoring of ketone bodies has been demonstrated in a phantom gel skin-mimicking model. The ability to detect HB along with glucose and lactate on a single microneedle array has been demonstrated. These findings pave the way for CKM and for the simultaneous microneedle-based monitoring of multiple diabetes-related biomarkers toward a tight glycemic control.
The V-cb puzzle: An update
PHYSICS LETTERS B
Authors: Gambino, Paolo; Jung, Martin; Schacht, Stefan
Abstract
We discuss the impact of the recent untagged analysis of B-0 -> D*l (nu) over bar (l)) decays by the Belle Collaboration on the extraction of the CKM element vertical bar V-c(b)vertical bar and provide updated SM predictions for the b -> c tau nu observables R(D*), P-tau, and F-L(D*). The value of vertical bar V-cb vertical bar that we find is about 2 sigma from the one from inclusive semileptonic B decays, and is very sensitive to the slope of the form factor at zero recoil which should soon become available from lattice calculations. (C) 2019 The Authors. Published by Elsevier B.V.