A lab in a bento box: an autonomous centrifugal microfluidic system for an enzyme-linked immunosorbent assay
ANALYTICAL METHODS
Authors: Abe, Takaaki; Okamoto, Shunya; Taniguchi, Akinobu; Fukui, Michiyasu; Yamaguchi, Akinobu; Utsumi, Yuichi; Ukita, Yoshiaki
Abstract
In this paper, we report on the demonstration of a portable immunoassay system consisting of a small centrifugal microfluidic device driver (bento box) and a centrifugal microfluidic device made of polypropylene and fabricated by injection molding. The bento box consists of a cheap DC motor and an Arduino microcontroller. It has a simple structure and is the size of a bento box, that is, 150 x 150 x 100 (W x D x H) mm(3). The developed device can automatically execute an enzyme-linked immunosorbent assay (ELISA) process under a steady rotating condition because it was designed based on the principle of CLOCK, which we previously presented. Here, we first executed an ELISA using a system consisting of the bento box and a device made of polydimethylsiloxane (PDMS) and compared it with a servo-controlled device driver. It was confirmed that the results of the bento box were consistent with those of the servo-controlled device driver. The limit of detection (LOD) using the bento box was 0.759 ng ml(-1). Therefore, the controllability of the bento box was demonstrated. Next, we evaluated the injection-molded device through multi-step fluid control. We confirmed, through real-time observation of the device, that accurate flow control in the designed ELISA procedure was executed. Lastly, ELISA was employed for the measurements of mouse IgG using the system consisting of the bento box and the polypropylene device. The system performed all fluidic controls within 12 min; we confirmed the specificity of the system, and the LOD was 0.320 ng ml(-1).
A novel glycosidase plate-based assay for the quantification of galactosylation and sialylation on human IgG
GLYCOCONJUGATE JOURNAL
Authors: Rebello, Osmond D.; Gardner, Richard A.; Urbanowicz, Paulina A.; Bolam, David N.; Crouch, Lucy I.; Falck, David; Spencer, Daniel I. R.
Abstract
Changes in human IgG galactosylation and sialylation have been associated with several inflammatory diseases which are a major burden on the health care system. A large body of work on well-established glycomic and glycopeptidomic assays has repeatedly demonstrated inflammation-induced changes in IgG glycosylation. However, these assays are usually based on specialized analytical instrumentation which could be considered a technical barrier for uptake by some laboratories. Hence there is a growing demand for simple biochemical assays for analyzing these glycosylation changes. We have addressed this need by introducing a novel glycosidase plate-based assay for the absolute quantification of galactosylation and sialylation on IgG. IgG glycoproteins are treated with specific exoglycosidases to release the galactose and/or sialic acid residues. The released galactose monosaccharides are subsequently used in an enzymatic redox reaction that produces a fluorescence signal that is quantitative for the amount of galactosylation and, in-turn, sialylation on IgG. The glycosidase plate-based assay has the potential to be a simple, initial screening assay or an alternative assay to the usage of high-end analytical platforms such as HILIC-FLD-MSn when considering the analysis of galactosylation and sialylation on IgG. We have demonstrated this by comparing our assay to an industrial established HILIC-FLD-MSn glycomic analysis of 15 patient samples and obtained a Pearson's r correlation coefficient of 0.8208 between the two methods.