Reducing Fluoroscopic Radiation Exposure During Endomyocardial Biopsy in Pediatric Transplant Recipients
PEDIATRIC CARDIOLOGY
Authors: Gossett, Jeffrey G.; Sammet, Christina L.; Agrawal, Anya; Rychlik, Karen; Wax, David F.
Abstract
Endomyocardial biopsy (EMB) with fluoroscopy is used for rejection surveillance in pediatric heart transplantation. Lowering frame rate may reduce radiation, but decreases temporal resolution and image quality. We undertook a quality initiative reducing frame rate from 10 frames per second (FPS) to 5 FPS. To assess whether lowering frame rate can reduce radiation exposure without compromising safety, data on EMBs from 9/2009 to 4/2013 without angiography or intervention were reviewed. Effective dose was calculated from dose area product (DAP) and fluoroscopy time. Complications were reviewed. Independent t test compared pre- and post-data and a general linear model were used to control for confounders. Paired t test of most proximate data was used for pts with EMB before and after our change. Eighty-six patients had 543 EMB. After adjusting for weight, attending, and presence of a fellow, the lower FPS group had a 60.3% reduction in DAP (p < 0.0001) and 53.8% drop in effective dose (p < 0.0001). Fluoroscopy time did not differ. Twenty-eight pts had EMBs both before and after the FPS change. Pair-wise analysis of this group demonstrated a 33% reduction in DAP (p < 0.05) and 37% drop in effective dose (p < 0.01), without difference in fluoroscopy time. No patient had an increase in TR > 1 grade by ECHO. There were no deaths or perforations. Lowering the frame rate reduces radiation exposure by > 50% without compromising safety. Efforts to further minimize radiation exposure of this vulnerable population should be considered.
External quality control of phenotypic drug susceptibility testing for Mycobacterium tuberculosis in China
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES
Authors: Shu, Wei; Du, Jian; Liu, Yuhong; Wang, Yufeng; Huo, Fengmin; Jiang, Guanglu; Li, Liang; Pang, Yu
Abstract
The aim of our study was to evaluate the performance of conventional drug susceptibility testing (DST) among the tuberculosis (TB)-specialized hospitals in China. A total of 40 hospitals participated in the external quality assurance program for assessment of DST results from each hospital. The sensitivity, specificity, and accuracy of DST were analyzed. The mean accuracy was 96.5% for isoniazid (INH), 95.8% for rifampin (RIF), 97.0% for ethambutol (EMB), 96.8% for ofloxacin (OFX), 97.1% for kanamycin (KAN), 96.1% for amikacin (AMK), and 93.6% for capreomycin (CAP), respectively. Of the 40 participating laboratories, 4 (10.0%) and 6 (15%) failed to achieve 90% accuracy for INH and RIF, respectively. In addition, six hospitals (15%) were confirmed as certified to provide reliable DST results for both first-line and second-line drugs. The certified proportion for DST dropped from 73.9% in the non-western region to 59.2% in the western region. The significant difference was observed in the certified proportion for first-line drugs between the western and non-western region (P = 0.013). Our results demonstrate that the quality of phenotypical DST is frequently unsatisfactory, with approximately one-third of participated laboratories failing to produce certified phenotypical DST results. In addition, the uncertified laboratories majorly come from the western region in China.