Medica 2026
Nov 16-19, 2026 - Düsseldorf, Germany

ELISA Kit for Human Papillomavirus 16 E7 Oncoprotein

Human Papillomavirus (HPV) is a widespread group of viruses, with over 100 different types identified. Among them, HPV16 is recognized as one of the high-risk types, strongly associated with the development of various cancers, particularly cervical cancer, as well as anal, vaginal, vulvar, penile, and oropharyngeal cancers. The E7 oncoprotein encoded by HPV16 plays a pivotal role in the carcinogenic process. It disrupts the normal function of the pRb (retinoblastoma) tumor suppressor protein, leading to uncontrolled cell proliferation and the initiation of malignant transformation.

What is HPV-16 E7 Oncogenic Protein?

Human papillomavirus (HPV) is a group of small, non enveloped double stranded DNA viruses that can infect the skin and mucous membranes. HPV is classified into high-risk and low-risk types based on its carcinogenic potential. Among all high-risk HPV types, HPV-16 is the most common and dangerous type, associated with approximately 50% of cervical cancer cases worldwide, as well as the majority of anal, vulvar, vaginal, penile, and oropharyngeal cancers.

E7 is a key oncogenic protein encoded by the HPV-16 genome. It works together with another carcinogenic protein E6 and plays a central role in the virus driven cellular carcinogenesis process. The E7 protein hijacks the normal regulatory pathways of host cells through a series of complex molecular mechanisms, causing unlimited proliferation and ultimately leading to the formation of malignant tumors.

Figure 1. Antibody-drug conjugates (ADCs).Figure 1. Structure of Human Papillomavirus 16.

Technology Platform

Sample Type Compatibility

  • Human Serum
  • Human Plasma
  • Animal Matrices (Mouse/Rat/Primate)
  • Cell Culture Supernatants
  • Tissue Homogenates

Sensitivity Profile

  • High Sensitivity (LOD: 0.1–0.5 ng/mL)
  • Matrix Interference-Optimized (validated in serum/plasma)

Kit Features

  • Pre-Coated Microplate (anti-DM1 antibody)
  • Complete Reagent Set (standards, HRP conjugate, buffers, substrate)
  • Automation-Compatible (96-well format for high-throughput)
  • Wide Dynamic Range (0.1–390 ng/mL)

Key Components & Specifications

Key Features and Benefits

  • High Sensitivity and Specificity: The optimized antibody pair ensures accurate detection of the target protein, minimizing cross-reactivity with other related proteins.
  • Quantitative Results: The kit provides a quantitative measure of E7 oncoprotein concentration, enabling precise data analysis for research studies.
  • Broad Sample Compatibility: Validated for use with a variety of biological samples, including cell lysates and tissue homogenates.
  • Convenient and Ready-to-Use: All necessary reagents are included in the kit, with pre-coated plates and detailed instructions for a streamlined workflow.
  • Reliable and Reproducible: Manufactured under strict quality control standards to ensure consistent performance and reliable results across experiments.

Technical Specifications

  • Assay Principle: Sandwich ELISA
  • Detection Target: Human Papillomavirus 16 E7 Oncoprotein
  • Sample Types: Cell lysates, tissue homogenates
  • Assay Time: Approximately 3.5 hours
  • Detection Range: Refer to the product-specific technical data sheet for the exact range.
  • Standard Curve: Provided with the kit for accurate quantification.

Components Provided

  • Pre-coated 96-well Microplate (12 strips of 8 wells)
  • Recombinant HPV 16 E7 Standard (Lyophilized or ready-to-use)
  • Biotin-conjugated Detection Antibody
  • Streptavidin-HRP (SA-HRP) Conjugate
  • Assay Diluent Buffer (10X)
  • Wash Buffer Concentrate (25X)
  • TMB Substrate Solution (Ready-to-use)
  • Stop Solution (1M Sulfuric Acid)
  • Plate Sealers

Applications

Cancer Research

Cancer Research

It is extensively used in studies investigating the role of HPV16 E7 oncoprotein in cancer development. Researchers can use the kit to measure the expression levels of E7 in different cell lines, tissues, and animal models, helping to elucidate the molecular mechanisms underlying HPV-induced carcinogenesis.

Therapeutic Efficacy Evaluation

Therapeutic Efficacy Evaluation

In the development and testing of new therapies targeting HPV16-related cancers, the kit is useful for evaluating the efficacy of the treatment. By measuring the levels of E7 oncoprotein before and after treatment, researchers and clinicians can determine whether the therapy is effective in reducing the expression of this oncoprotein, which is a key indicator of therapeutic success.

ELISA Kit for Human Papillomavirus 16 E7 Oncoproteins

ParameterDetails
Product nameHuman HPV 16 E7 Oncoprotein ELISA Kit
SampleCell lysates, tissue lysates, cervical smears, plasma, serum
Intended UseHuman HPV16 E7 Oncoprotein ELISA Kit is an enzyme immunoassay developed for detection and quantitation of the Human Papillomavirus Type 16 E7 protein from cell lysates, tissue lysates, cervical smears, plasma and serum. Each kit provides sufficient reagents to perform up to 96 assays including standard curve and HPV16 E7 samples.
SensitivityThe kit has detection sensitivity limit of 31 pg/mL HPV16 E7.
General DescriptionHuman papillomavirus (HPV) is a large group of more than 150 related DNA viruses. HPV is named for the warts (papillomas) some types can cause and is spread through direct skin-to-skin contact. Although most HPV infections cause no symptoms and resolve spontaneously, some persist and result in warts or precancerous lesions. Of the more than 150 types, over 40 types are known to be transmitted through sexual contact and make it the most commonly sexually transmitted infection (STI).
Standard CurvePharmacokinetics (PK) Studies

Data Analysis

The Significance Of Studying E7 Oncogenic Protein

The in-depth study of HPV-16 E7 oncogenic protein is of great significance:

Advantages of Salmonella Enteritidis ELISA Kit

High Specificity

Utilizes highly specific monoclonal antibodies that show no significant cross-reactivity with other HPV types (e.g., HPV 18, 31, 33) or other common biological interferents. This ensures you are measuring HPV 16 E7 specifically.

Comprehensive Analysis

The kit includes a full set of standards for generating a standard curve, allowing for precise quantitative analysis rather than just qualitative detection. All reagents, including standards, are provided pre-formulated and optimized for convenience.

Accuracy

The accuracy of the kit is evaluated by spiking known concentrations of HPV16 E7 oncoprotein into different biological matrices (such as serum, cervical swab extracts). The recovery rate indicating that the kit can accurately quantify the E7 oncoprotein in various sample types.

Conclusions

In conclusion, the ELISA Kit for Human Papillomavirus 16 E7 Oncoprotein is a valuable tool for the detection and quantification of HPV16 E7 oncoprotein. With its high sensitivity, specificity, and reliability, it serves as an important asset in both research and clinical settings, contributing to the understanding, diagnosis, and treatment of HPV16-related cancers.

Frequently Asked Questions (FAQ)

Antibody FAQs

Still have questions?

Contact Us

Lyse cells in a suitable non-denaturing lysis buffer (e.g., RIPA buffer) supplemented with protease inhibitors. Centrifuge the lysate at 10,000-15,000 x g for 10-15 minutes to remove insoluble debris. The resulting supernate should be diluted appropriately in the provided assay diluent before use in the ELISA.

The sample must be further diluted in the provided assay diluent and re-run. We recommend testing several dilutions of a new sample type to ensure the result falls within the linear range of the standard curve for accurate quantification.

The 96-well format is amenable to medium-throughput screening. For true HTS, please contact us to discuss automated liquid handling compatibility and potential bulk purchasing options.

Inquiry Basket
loading Loading ......

Inquiry

Inquiry