For the quantitative measurement of Vaccinia Capping Enzyme in biological products. It is applicable to theoptimization of purification process of biological products, impurity control of intermediate process and release testing of final products.
Contents of Kit
No.
Components
Size
Storage Conditions
1
Standard, Lyophilized
2vials
2-8°C
2
Coated Plate
8wells×12 strips
2-8°C
3
Dilution Buffer 1
45mL×1vial
2-8°C
4
Dilution Buffer 2
30mL×1vial
2-8°C
5
Wash Buffer(20×)
50 mL×1vial
2-8°C
6
Detection Antibody (100×)
120μL×1tube
2-8°C
7
Streptavidin-HRP(500×)
40μL×1tube
2-8°C
8
TMB Substrate
15mL×1vial
2-8°C
9
Stop Solution
10mL×1vial
2-8°C
10
Sealing Film
4 pieces
2-8°C
Storage
This kit should be stored at 2-8°C before the kit opening. The kit has a shelf life of 12 months from the date of manufacture. After opening, store the kit at 2-8°C and use within 30 days
Detection Range
0.125 - 8 ng/mL
Sensitivity
Limit of quantification: 0.125 ng/mL
General Description
The cap structure is a modification at the 5' end of eukaryotic mRNA formed after transcription. Vaccinia capping enzyme is an effective catalyst in forming this cap structure. Therefore, for biological products utilizing vaccinia capping enzyme, residual levels must be quantitatively assessed. This ELISA kit employs a double-antibody sandwich format to detect vaccinia capping enzyme residues. Standards and samples are added to microplate wells pre-coated with an anti-vaccinia capping enzyme antibody. A biotin-labeled detection antibody is added, followed by Streptavidin-HRp, forming an antibody-antigen-biotinylated antibody-Streptavidin-HRP complex.TMB substrate is then added for color development. TMB turns blue upon catalysis by HRP and transitions to yellow after the addition of stop solution. The intensity of the yellow color is directly proportional to the amount of capping enzyme present in the sample.
Standard Curve
Standard Curve Fitting: Plot standards' concentrations(x-axis) against OD450 values (y-axis). Apply 4-parameter logistic(4PL) regression for curve fitting. The standard curve is obtained by 4-parameter fitting with the theoretical standard concentrations and the corresponding OD values (as shown in the figure below).
Citations
Publication ()
Have you cited DEIA-BZ003 in a publication? Let us know and earn a reward for your research.
Creative Diagnostics products are for RESEARCH USE ONLY, please make sure your review is research based.
Required fields are marked with *
Terms and conditions:
We will select high-quality review customers and offer a $30 coupon for your next purchase.
All product reviews must be submitted in the English language.
Creative Diagnostics will not share any personal information of applicants, and all information will be treated with strict confidentiality and will not be sold or disclosed to a third party.