Magic Fast™ FITC Conjugation Kit

Creative Diagnostics has designed the Magic Fast™ FITC conjugation kit to enable the direct labeling of any proteins, antibodies, antibody fragments, peptides or other biomolecules with available amine groups to accelerate life science fundamental research and the development of the diagnostic kit. Our technology can be used to label both small and large quantities of biomolecules with ease. The researcher simply pipettes their materials into the vial and incubates for 1 hour.

Performance

  • Material selection: Any proteins, antibodies, antibody fragments, peptides or other biomolecules with available amine groups.
  • Reactivity: free -NH2.
  • Linkage stability: Activation of proprietary reagents within the offered solution results in directional covalent bonding of FITC to the biomolecules.
  • East-to-go: By circumventing desalting or dialysis steps that commonly interrupt traditional antibody conjugation procedures, the researchers get the conjugated biomolecules after simply mixing the materials together.
  • Rate: Instant reaction; the whole process less than 1.5 hours.
  • Consistence: Good reproducibility from batch to batch.

Kit Components

Cat.FITCRegulating BufferDMSOPurification ColumnCollection Tube
CD4002-1 mg1 vial50 µl150 µl2 Columns2 Tubes
Note: The kit above is designed for antibodies. Please follow same technical tips if required.

Recommended Application Notes

  • Regulating Buffer (µl) / Material (µl): 10 µl / 100 µl
  • Material (µg) / FITC (µl): 100 µg / 4 µl

Each laboratory should determine an optimum amount for use in its particular application.

Buffer Considerations

Buffer Components & Conditions
Amine free buffer
(e.g HEPES, MES, MOPS and phosphate)
Yes
Borate bufferYes
Chelating agents (e.g. EDTA)Yes
GlycerolNo
GlycineNo
Material supplied in ascites fluid, serum, hybridoma or tissue culture mediaNo
MerthiolateNo
Non-buffering salts (e.g. sodium chloride)Yes
Other biomoleculesPrimary amines required
PeptidesYes
pH6.5-8.5
ProclinNo
ProteinsNo
Purified antibodyYes
Sodium AzideNo
SugarsYes
Thiomersal / ThimerosalNo
TrisNo

Storage

  • FITC: Stable at 2-8℃ for 1 year. Keep in dark place.
  • Regulating Buffer: Stable at 2-8℃ for 1 year.
  • DMSO: Stable at 2-8℃ for 1 year.
  • Conjugated Materials: Stable at 4℃ for 1 year.

Attention

  • Keep the kit at 2-8℃, do not freeze.
  • Kit components may be reversed during transportation, please centrifuge before use.
  • The FITC should be used and prepared on the spot, and the dissolved FITC cannot be stored for a long time.
  • The buffer in the purification column contains the toxic component sodium azide (NaN3), so avoid contact with skin, eyes and mucous membranes when used.
  • DMSO has certain toxicity, which is permeable to human skin and irritating to eyes. Avoid contact with skin, eyes and mucous membrane when used.
  • The operation of dialysis, concentrating and concentration determination of antibodies before conjugating cause the loss of antibodies, so the appropriate usage of antibodies should be prepared according to the specific situation before conjugating.

Assay Procedure

  1. Equilibrate all materials and prepared reagents to room temperature prior to use.
  2. Centrifuge the lyophilized FITC for a few seconds.
  3. Add 50 µl of DMSO to the lyophilized FITC and mix gently.
  4. Add 10 µl of Regulating Buffer to each 100 µl of antibody (the recommended antibody concentration is 1-2mg/ml) and mix gently.
  5. Add 4 µl of FITC solution to each 100 µg of antibody be labeled and mix gently.
  6. Place the antibody-FITC mixture on a horizontal shaker for 1 hours in the dark at room temperature (22-25℃).
  7. After incubating, the conjugation is required purification.
  8. Centrifuge the Purification Column at 3000rpm for 2min.
  9. Move the Purification Column to a new Collection Tube and add the antibody-FITC coupling to the Purification Column. If the sample volume is less than 50 µl, the liquid should first be filled to 50 µl using the buffer in the Collection Tube. The maximum sample volume should not exceed 100 µl.
  10. After the sample penetrated into the packing, centrifuge at 3000rpm for 2min.
  11. The antibody-FITC should be stored at 4℃.

Magic Fast™ HRP Conjugation KitFigure 1. Assay Procedure of Magic Fast™ FITC Conjugation Kit

Note: The kit above is designed for antibodies, but works well for any amine containing biomolecule. Please follow same technical tips if required.

Cat No.Product name
CD4002-1 mgMagic Fast™ FITC Conjugation Kit (1 mg)Inquiry
Note: The kit above is designed for antibodies, but works well for any amine containing biomolecule. Please follow same technical tips if required.
Inquiry Basket