Medica 2026
Nov 16-19, 2026 - Düsseldorf, Germany

Human Triiodothyronine (T3) ELISA Kit For Accurate Quantification of Thyroid Function

The Human Triiodothyronine (T3) ELISA Kit is a sophisticated in vitro diagnostic tool designed for the precise quantification of total triiodothyronine in human serum and plasma. Utilizing a competitive enzyme-linked immunosorbent assay (ELISA) format, this kit provides clinicians and researchers with a reliable method for assessing thyroid function and diagnosing thyroid disorders. With its optimized protocol and ready-to-use components, the kit delivers excellent reproducibility and sensitivity, making it an essential asset for clinical laboratories, research institutions, and healthcare facilities involved in endocrine evaluation and metabolic studies.

Triiodothyronine (T3)

Triiodothyronine (T3) is the biologically active thyroid hormone that plays a crucial role in regulating metabolic processes throughout the body. While produced in smaller quantities than thyroxine (T4), T3 possesses significantly greater biological activity and serves as the primary mediator of thyroid hormone effects on target tissues. The majority of circulating T3 is bound to carrier proteins, with only the free fraction being biologically active. Measurement of total T3 levels provides valuable clinical information for diagnosing various thyroid disorders, including hyperthyroidism, hypothyroidism, and thyroid hormone resistance syndromes.

Thyroid hormones.Figure 1. Thyroid hormones.

Introduction

The significance of T3 quantification extends beyond routine thyroid function assessment. In clinical practice, T3 measurements are particularly important for diagnosing T3 toxicosis, monitoring thyroid cancer patients, and evaluating the effectiveness of thyroid replacement therapy. Research applications include investigating metabolic disorders, studying the hypothalamic-pituitary-thyroid axis, and exploring the role of thyroid hormones in development and cellular function. This ELISA kit employs a competitive binding principle that ensures accurate detection of T3 across clinically relevant concentrations, providing reliable results for both diagnostic and research purposes.

Technology Platform

Sample Compatibility

  • Human Samples
  • Cell culture
  • Serum, plasma

Sensitivity Range

  • High Sensitivity
  • Broad Dynamic Range
  • Low Limit of Detection
  • High Precision

Main Uses

  • Diagnosis
  • Risk screening
  • Outbreak screening

Product Specifications and Performance

Product Specifications

  • Detection Method: Competitive ELISA
  • Sample Type: Human serum, plasma
  • Assay Time: Approximately 90 minutes
  • Detection Range: 0.5-10 ng/mL
  • Sensitivity: <0.2 ng/mL
  • Precision: Intra-assay CV <8%; Inter-assay CV <10%
  • Specificity: High specificity for T3 with minimal cross-reactivity with T4 and other thyroid analogs

Intended Use & Research Applications

  • This kit is designed for professional use in clinical and research settings:
  • Clinical Diagnostics: Assessment of thyroid function and diagnosis of thyroid disorders.
  • Hyperthyroidism Evaluation: Detection of elevated T3 levels in Graves' disease and toxic nodular goiter.
  • Therapeutic Monitoring: Tracking thyroid hormone levels in patients undergoing treatment for thyroid disorders.
  • Research Applications: Investigating thyroid physiology, metabolic studies, and endocrine research.
  • Epidemiological Studies: Population-based thyroid function assessment.

Main Features of the Product

  • Specificity: Monoclonal anti-T3 antibodies target the unique iodinated phenolic ring of T3, eliminating cross reactivity with T4 (the main confounding factor in T3 detection) and ensuring accurate quantification of only active T3.
  • Rapid detection plan: The total detection time is less than 2 hours, which is shorter than most commercial T3 ELISA kits and can be used for high-throughput testing in large-scale studies (such as screening more than 50 clinical samples per day).
  • Low sample requirement: Each test only requires 50 μ L of sample, which is very suitable for studies with limited sample sizes (such as pediatric thyroid studies, elderly sarcopenia thyroid related studies).

Human Progesterone ELISA Kit

ParameterDetails
Product nameHuman T3 ELISA Kit
Sampleserum
Intended UseHuman T3 ELISA Kitis an Enzyme Immunoassay (EIA) for the quantitative determination of triiodothyronine (T3) in human serum. For professional use only.
StorageStore components of the kit at 2-8°C upon arrival up to the expiration date. For more detailed information, please download the following document on our website.

Application Advantage: Optimized for Clinical Research Samples

Triiodothyronine.

Unlike generic ELISA kits, this kit is tailored to real-world endocrine research needs:

Validated for EDTA/Heparin plasma (the most common plasma types in thyroid studies) and excludes citrate plasma (which binds T3 and causes false lows)—a detail many competing kits overlook.

The sample dilution buffer contains thyroid hormone stabilizers (e.g., bovine serum albumin) to prevent T3 degradation during assay, critical for samples stored for > 24 hours.

Advantages

Exceptional Sensitivity

This kit is engineered for high sensitivity, capable of accurately quantifying the low levels of progesterone present in the follicular phase of the menstrual cycle and in men. This is essential for obtaining clinically meaningful data across all physiological states.

Time-Efficient Workflow

The competitive ELISA format allows for a rapid and simplified procedure. With pre-coated plates and optimized reagents, the entire assay can be completed in approximately 90 minutes, facilitating timely decision-making in both research and clinical settings.

High Specificity

The antibody used in this kit exhibits high affinity and specificity for progesterone, minimizing interference from other structurally similar steroid hormones. This ensures the accuracy and reliability of results, which is paramount for fertility assessment and pregnancy monitoring.

Conclusion

The Human Triiodothyronine (T3) ELISA Kit represents a reliable and accurate solution for the quantification of total T3 in clinical and research settings. With its exceptional analytical performance, user-friendly design, and robust reproducibility, this kit provides healthcare professionals and researchers with a valuable tool for assessing thyroid function and advancing our understanding of thyroid physiology. The combination of clinical utility and research flexibility makes this kit suitable for various applications, from routine diagnostic testing to investigative studies in thyroidology and metabolic research.

Frequently Asked Questions (FAQs)

Antibody FAQs

Still have questions?

Contact Us

A1: Elevated T3 levels are commonly seen in hyperthyroid conditions such as Graves' disease, toxic nodular goiter, and thyroiditis. Decreased T3 levels may occur in hypothyroidism, non-thyroidal illness (euthyroid sick syndrome), malnutrition, and during certain medications. T3 measurement is particularly valuable in diagnosing T3 toxicosis, where T3 is elevated while T4 remains normal.

A2: Serum samples should be collected using standard venipuncture techniques. Samples are stable for 24 hours at 2-8°C or for longer periods when stored at -20°C. Avoid repeated freeze-thaw cycles, as this may affect analyte stability and assay performance. Hemolyzed or lipemic samples may interfere with assay results and should be avoided.

A3: This T3 ELISA provides specific quantification of total triiodothyronine levels, complementing other thyroid tests including TSH, T4, and free T3 measurements. The competitive ELISA format offers excellent sensitivity and specificity for T3 detection, making it suitable for both routine clinical use and research applications. Results should be interpreted in the context of other thyroid function tests and clinical findings.

A4: Total T3 measures both protein-bound and free fractions of triiodothyronine, representing the overall T3 pool in circulation. Free T3 measures the biologically active fraction not bound to carrier proteins. While free T3 may better reflect biological activity, total T3 measurement remains clinically valuable and is affected by conditions that alter thyroid hormone binding proteins.

Inquiry Basket
loading Loading ......

Inquiry

Inquiry