Medica 2026
Nov 16-19, 2026 - Düsseldorf, Germany

Boldenone ELISA Test Kit: High Sensitivity Screening for Anabolic Steroids

The boldenone ELISA Test Kit is a professional in vitro diagnostic (or research-use) tool designed for high-sensitivity screening of boldenone, which is an anabolic steroid widely used illegally in sports, livestock breeding, and other fields. Based on the Enzyme-Linked Immunosorbent Assay (ELISA) principle, this kit enables rapid, accurate, and cost-effective qualitative or quantitative detection of boldenone residues in various samples (such as serum, urine, tissue homogenates, and feed extracts). It is widely applicable to sports anti-doping laboratories, food safety supervision institutions, veterinary inspection centers, and scientific research institutions, providing reliable technical support for controlling Boldenone abuse and ensuring public health and sports fairness.

Introduction

Boldenone, also known as 1,4-androstadien-17β-ol-3-one, is a synthetic anabolic steroid with strong muscle-building and growth-promoting effects. In sports, its illegal use can enhance athletic performance but causes serious health risks (e.g., liver damage, cardiovascular diseases, and hormonal disorders), violating the principles of fair competition. In livestock breeding, unauthorized addition of Boldenone to feed leads to residues in animal-derived foods (meat, milk, eggs), which may cause endocrine disruption and other health hazards when ingested by humans. Traditional detection methods for boldenone (such as liquid chromatography-mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS)) have high accuracy but require expensive equipment, professional operators, and long detection cycles—making them unsuitable for large-scale rapid screening.

Vasoactive peptide.Figure 1. Boldenone.

Technology Platform

Sample Compatibility

  • Human Samples
  • Cell culture
  • Serum, plasma

Sensitivity Range

  • High Sensitivity
  • Broad Dynamic Range
  • Low Limit of Detection
  • High Precision

Main Uses

  • Diagnosis
  • Risk screening
  • Outbreak screening

Product Specifications and Performance

Feature/Specification

  • Detection principle: direct competition ELISA method
  • Sample type: urine, serum, plasma, tissue homogenate
  • Sample volume: 50 μ L
  • Testing time: 70 minutes
  • Storage Conditions: 2-8 ° C
  • Sensitivity (IC50):please refer to the specific batch manual

Intended Use

  • Food safety and animal husbandry supervision: detect the illegal use of benzophenone in the urine, serum, or tissues of farmed animals such as cattle and pigs.
  • Sports anti doping screening: Testing athletes' urine samples for the presence of banned benzophenone and its metabolites.
  • Forensic and clinical toxicology research: used for evidence testing or academic research in related cases.

Product Features

  • High sensitivity: With a low detection limit, it can meet the detection requirements of strict residue limit standards.
  • Excellent specificity: The antibody is carefully screened for Boldenonee and has a low cross reactivity rate with other common synthetic metabolic steroids such as testosterone and tranbolone, resulting in accurate and reliable results.
  • Efficient and convenient: The sample pre-treatment is simple, the overall detection time is short (about 70 minutes), and high-throughput screening can be achieved.
  • Stable results: The optimized reagent formula ensures small intra - and inter plate coefficients of variation and good repeatability.
  • Ready to use reagent: provide pre coated Flat noodles and ready to use working fluid to minimize operating steps and human errors.

Three Core Advantages

  • Excellent screening efficiency: Compared to confirmation techniques such as chromatography-mass spectrometry, this kit can significantly reduce detection costs and time, making it an ideal choice for large-scale sample screening.
  • Excellent cost-effectiveness: Low cost per test, no need to rely on expensive large instruments and professional operators, easy to popularize and apply in various laboratories.
  • Flexible detection capability: Verified to be applicable to various sample matrices (urine, serum, tissue homogenates), providing a unified solution for detection needs in different field.

Human Progesterone ELISA Kit

ParameterDetails
Product nameBoldenone ELISA Kit
SampleUrine, Blood, Oral Fluid, Forensic Matrices
General DescriptionCD's Boldenone ELISA (Enzyme-Linked ImmunoSorbent Assay) test kit is a qualitative one-step kit designed for use as a screening device for the detection of drugs and/or their metabolites. The kit was designed for screening purposes and is intended for forensic use only. It is recommended that all suspect samples be confirmed by a quantitative method such as gas chromatography/mass spectrometry (GC/MS).
StorageThis kit can be used until the expiration date on the label when stored refrigerated at 2-8°C. Store controls frozen if not used within 10 days. Note: Some kits require controls to be stored frozen immediately upon receipt. Reference kit label for details.

Why This ELISA Kit is a Better Choice

Boldenone.

Compared with other boldenone detection methods or similar ELISA kits, this product has obvious competitive advantages:

More flexible sample adaptability: Some kits only support a single sample type. This kit, through optimized buffer systems, can handle serum, tissue, and feed samples with simple pre-treatment, reducing the need for multiple kit purchases.

Cost-effectiveness: Compared with LC-MS/GC-MS, the kit has lower equipment investment and per-sample detection costs, suitable for long-term routine screening.

Complete Supporting Reagents: The kit provides all necessary reagents (including standards and quality controls), avoiding the trouble of purchasing and matching reagents separately.

Advantages

Operational Convenience Advantage

The kit simplifies complex detection processes (e.g., no need for professional instrument operation or complex sample purification). With a detailed instruction manual, even personnel without advanced laboratory experience can complete detection after simple training, reducing the threshold for use.

Reliability and Compatibility Advantage

Under strict quality control, the kit's sensitivity, specificity, and precision meet international technical standards; it is compatible with common microplate readers on the market (no need for dedicated equipment), ensuring seamless integration with existing laboratory workflows.

High Specificity for Accurate Clinical Assessment

The antibody used in this kit exhibits high affinity and specificity for progesterone, minimizing interference from other structurally similar steroid hormones. This ensures the accuracy and reliability of results, which is paramount for fertility assessment and pregnancy monitoring.

Conclusion

The boldenone ELISA kit, with its high sensitivity, strong specificity, simple operation, and cost-effectiveness, effectively addresses the pain points of large-scale, rapid screening for boldenone. It not only provides a reliable technical tool for sports anti-doping (maintaining fair competition) and food safety supervision (protecting public health) but also supports scientific research in pharmacology and toxicology. Whether in government supervision institutions, third-party testing laboratories, or scientific research units, this kit can meet diverse detection needs and is an ideal choice for boldenone screening.

Frequently Asked Questions (FAQs)

Antibody FAQs

Still have questions?

Contact Us

A1: It's not possible. The ELISA method is commonly used for initial screening detection. For positive samples, it is recommended to use confirmation methods such as GC-MS or LC-MS/MS for final confirmation and quantification.

A2: Usually requires simple dilution and centrifugation. Please refer to the product manual for specific sample pre-processing methods, as different sample types may have different processing methods.

A3: This reagent kit is mainly designed for detecting the prototype of benzophenone. But its antibodies may have some cross reactivity with certain major metabolites, thus achieving indirect monitoring. To specifically detect a certain metabolite, it is necessary to confirm the cross reaction data of the kit.

A4: A 96 well plate reagent kit, with standard curves and quality control wells set, can typically detect about 40 unknown samples (each sample is double well).

Inquiry Basket
loading Loading ......

Inquiry

Inquiry