Assessment of Toxic Effects of Chloramphenicol in Rats and its Amelioration by Coconut water
RESEARCH JOURNAL OF CHEMISTRY AND ENVIRONMENT
Authors: Chetan, Dubey; Abhilasha, Saxena; Rakhi, Gupta; Poonam, Singh; Bansode, F. W.; Singh, R. K.
Abstract
Chloramphenicol was administered at dose levels of 150 mg/kg in rats for 14 days which caused significant haematotoxicity and hepatotoxicity. Haematotoxicity and hepatotoxicity were reversed with the use of coconut water (20 ml/kg) in 14 Days establishing that coconut water has potential for amelioration of chloramphenicol toxicity. Glucuronidation of chloramphenicol followed by its elimination from the body is done by vitamins of group B (flavins) present in coconut water on stimulation of metabolism, of drug. Abundance of its aqueous enhances the dilution effect which is responsible for rapid increase in degree of absorption of chemicals in gastrointestinal tract.
UPLC-MS/MS determination of florfenicol and florfenicol amine antimicrobial residues in tilapia muscle
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
Authors: Orlando, Eduardo Adilson; Costa Roque, Aline Gabriela; Losekann, Marcos Eliseu; Colnaghi Simionato, Ana Valeria
Abstract
Despite the benefits to fish farmers, the use of antimicrobials in aquaculture has concerned consumers and competent authorities. The indiscriminate use of such substances promotes the emergence of resistant microorganisms, decreases the effectiveness of treatments, and causes possible toxic effects in humans. In Brazil, florfenicol is the only antimicrobial registered for use in aquaculture and is often used in tilapia in cage creation. Thus, this study aimed to develop a method for determination of florfenicol residues and its metabolite florfenicol amine in tilapia fillet by UPLC-MS/MS. Analytes were extracted with ethyl acetate, followed by liquid-liquid partition clean-up with hexane and SPE. The sorbents C18, phenyl and HLB-Oasis were evaluated by SPE. Phenyl sorbent showed the best results, and the extraction conditions were optimized in the sample matrix with fractional factorial design 2(4-1). The analytes were separated on a C18 chromatographic column (50 x 2.1 mm x 1.7 mu m) using water (A) and acetonitrile (B) as mobile phase at a flow rate of 0.3 mL min(-1) with a linear gradient (in% B): 0-2.0 min: 20%; 2.0-2.5 min: increase to 90%; 2.5-3.5 min: 90%; 3.0-3.5 min: decrease to 20%; 4.0-5.0 min: 20%. The analytes were monitored in a MS/MS triple quadrupole system by MRM mode with transitions at m/z 356.1 > 336.1 (florfenicol) and m/z 248.1 > 130.1 (florfenicol amine). The optimized method was validated obtaining LOQ values of 3 and 25 ng g(-1) for florfenicol and florfenicol amine, respectively, precision between 20 and 36%, absolute extraction efficiency between 38 and 80%, and adequate linearity. The method was applied to samples intended for human consumption, and within the 15 evaluated samples, only one showed florfenicol residue at 30 ng g(-1), which is below the maximum residue limit established in Brazil. (C) 2016 Elsevier B.V. All rights reserved.