Mechanism of the effect of 2, 2 '-azobis (2-amidinopropane) dihydrochloride simulated lipid oxidation on the IgG/IgE binding ability of ovalbumin
FOOD CHEMISTRY
Authors: Zhang, Jing-jing; Tu, Zong-cai; Wang, Hui; Hu, Yue-ming; Du, Peng-cheng; Yang, Yi-peng
Abstract
In this work, the mechanism of the effect of lipid oxidation on the IgG/IgE binding ability of ovalbumin (OVA) was investigated via the peroxyl radicals produced by 2, 2'-azobis (2-amidinopropane) dihydrochloride to simulate lipid oxidation. Results showed that the structure of OVA unfolded partially with an increase in oxidation degree, leading to the exposure of the allergenic epitopes and increasing the IgG/IgE binding ability of OVA. Nine oxidation sites were found on the a-helix, and these sites may unwind the a-helix and expose the allergenic epitopes on the OVA surface, leading to antibody recognition and combination. Consequently, the IgG/IgE binding ability of OVA was increased. In conclusion, the allergenic capacity of OVA can be promoted by modifying peroxyl radical oxidation in processing egg products.
Rapid Collection of Human Rectal Secretions Using OriCol Devices Is Suitable for Measurement of Mucosal Ig without Blood Contamination
JOURNAL OF IMMUNOLOGY
Authors: Czartoski, Julie; Lemos, Maria P.; Fong, Youyi; Mize, Gregory J.; Konchan, Anne; Berger, David; Maenza, Janine; McElrath, M. Juliana
Abstract
Measurements of IgG and IgA in human rectal secretions are used to evaluate the Abs elicited by HIV vaccines or the bioaccumulation following immunoprophylaxis at the sites of HIV exposure. To improve sampling methods and tolerability of the procedure, we optimized a balloon device (OriCol) for rectal microbiome sampling requiring 10 second inflation and compared this method to a 5 minute collection using sponges. Lubrication of the device did not interfere with IgG, IgA, or hemoglobin ELISA. Lubricated OriCols inflated to 30 cc minimized hemoglobin contamination (<4.68 ng/ml) compared with collections with two sponge types (Weck-Cel: 267.2 ng/ml, p < 0.0001; and Merocel: 59.38 ng/ml, p = 0.003). Median human serum albumin for OriCols was 14.9 mu g/ml, whereas Merocels and Weck-Cels were 28.57 mu g/ml (p = 0.0005) and 106.2 mu g/ml (p = 0.0002), respectively. Consistent with reduced systemic contamination, the median IgG measured in OriCol-collected rectal secretions (986 ng) was lower than secretions from sponges (Weck-Cel: 8588 ng, p < 0.0001; Merocel: 2509 ng, p = 0.0389). The median IgA yield of samples using the OriCol method (75,253 ng) was comparable to that using Merocel (71,672 ng; p = 0.6942) but significantly higher than Weck-Cel sponges (16,173 ng, p = 0.0336). Median recovery volumes for OriCols were 800 mu l, whereas Merocels and WeckCels were 615 mu l (p = 0.0010) and 655 mu l (p = 0.0113), respectively. The balloon device was acceptable among 23 participants, as 85.1% experiencing their first collection ranked it as "seven: acceptable - a lot" or "six: acceptable - somewhat" in a seven-point Likert scale. Therefore, lubricated OriCols inflated to 30 cc allowed for a rapid, well-tolerated, blood-free collection of human rectal secretions.